ARTICULATED CABLE PIPE
ARTICULATED CABLE PIPE
1. Name: Submarine Cable Protection Pipe
2. Effective Installed Length/segment pair : 500mm
3. Minimum Internal Diameter : 40mm - for cables up to 35mm diameter
4. Wall Thickness8mm, 9mm,10mm,14mm
5. Material : Ductile Iron
6. Tensile Strength / Elongation: 400MPa / 15% elongation
7. Impact Resistance≥7.5kJ
8. Minimum Bend Diameter : 4.0m;